WPT for medical application with a nonsymmetrical pair of spiral resonator and self-matching rectifier
عنوان المشروع | WPT for medical application with a nonsymmetrical pair of spiral resonator and self-matching rectifier |
---|---|
ملخص فكرة المشروع | a WPT nonsymmetrical pair<br /> of spiral resonators with a lumped elements on the transmitter<br /> side only and a compact receiver designed for biomedical im-<br /> plant applications, with high efficiency. the system achieves an<br /> efficiency of 68.89% with 16mm Rx and 81% with a symmetric<br /> 30mm Rx at operation frequency of 433MHz at a distance of<br /> 20mm at air as a medium, the resonator consists of a main<br /> inner loop for matching at 50Ωand outer loop with three<br /> circular turns to increase coupling, the receiver dimensions are<br /> finely tunes to eliminate the need of lamped element at it’s<br /> side, it also presents an innovative rectifier system coupled with<br /> a highly efficient impedance matching network, tailored for<br /> wireless power transfer (WPT) applications. Utilizing a novel<br /> self-matched rectification technique, the design ensures precise<br /> impedance control by employing a parallel capacitor with the<br /> rectifying diode, combined with a series inductor to form a<br /> compact and efficient unit cell. This approach not only simplifies<br /> the impedance matching process but also enhances overall system<br /> performance. The proposed rectifier achieves maximum efficiency<br /> 55.2% at the input power 0dB when the frequency 431MHz with<br /> size area 0.2925 cm2, even under load equal 4KΩ. |
المشكلة التي يحلها المشروع | Many patients require for their treatment to implant some battery-powered electronic medical devices, such<br /> devices when the battery in discharged required medicals surgery to replace the battery, and that solution was<br /> inconvenient.<br /> development in the wireless charging technology will enable the engineers to use a chargeable battery and<br /> relay on the wireless charging to avoid any unnecessary surgeries. |
اتجاهات المشروع |
+تحسين جودة الخدمات الصحية
+حلول تكنولوجية لتحسين جودة الحياة +الفيزياء |
هدف المشروع | Our project is to develop such system to achieve the maximum power transfer efficiency possible with the<br /> smallest dimensions of a Rx and Tx, taking in consideration the SAR limits be under the recommended values |
المخرجات الرئيسية من المشروع | The WPT system is considered of three main parts: 1- a transmitter 2- a receiver 3- and a rectifier. |
المرحلة الحالية | نموذج أولي جاهز |
نموذج عمل | Full paper |
هل المشروع حاصل على براءة اختراع أو ملكية فكرية؟ | لا |
?هل المشروع حصل على دعم أو تمويل سابقًا | لا |
المستفيدون من المشروع | patients with Cardiac pacemaker (and similer devices) implanted |
السوق المستهدف | سوق مصنعي الاجهزة الطبية الاكترونية |
استراتيجية دخول السوق | تقديم منتج اكثر كفاءة من المنافسين في السوق |
شركاء محتملون أو جهات مهتمة بدعم المشروع؟ | لا |
هل ترغب فى تحويل المشروع لشركة ؟ و معايير نجاح هذه الشركة | لا |
التحديات التي تواجه المشروع حاليًا | الوصول لأعلى كفاءة ممكنة بأقل حجم ممكن للمستقبل المزروع في جسم المريض |
الدعم الذى يحتاجه المشروع | توفير مختبرات أو مساحات عمل |
فيديو توضيحى للمشروع | |
دراسات /أبحاث داعمة للمشروع | Full paper |